命令记不住

登陆

MegaCli64 调整 Unconfigured(good) 问题

MegaCli64调整Unconfigured(good)问题

1.查看raid

[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL -NoLog|grep "Firmware state"
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Unconfigured(good), Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up

确认出现Unconfigured(good)问题

2.查看各项Count指标

[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PDList –aALL |grep -E "Slot Number|Media Error|Other Error|Predictive Failure Count|Firmware state|Last Predictive Failure Event Seq Number"
Slot Number: 0
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
Firmware state: Online, Spun Up
Slot Number: 6
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
Firmware state: Online, Spun Up
Slot Number: 7
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
Firmware state: Online, Spun Up
Slot Number: 8
Media Error Count: 0
Other Error Count: 3
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
Firmware state: Unconfigured(good), Spun Up

确认Slot Number值

3.执行导入命令

1.显示所有逻辑磁盘组信息

[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL


Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Mirror Data         : 558.375 GB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 2
Span Depth          : 1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 16.371 TB
Mirror Data         : 16.371 TB
State               : Degraded
Strip Size          : 64 KB
Number Of Drives per span:2
Span Depth          : 6
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: No



Exit Code: 0x00
[root@bj06-08u-node64-103 ~]#

2.显示所有的物理信息

/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL

3.执行导入命令

[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Import -aall
Foreign configuration is imported on controller 0.
Exit Code: 0x00

4.执行状态检测命令:

/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall |grep 'Firmware state'

4.查看恢复进度

确认rebuild进度

[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog  -physdrv[32:8] -a0

Rebuild Progress on Device at Enclosure 32, Slot 8 Completed 2% in 39 Minutes.

Exit Code: 0x00