MegaCli64调整Unconfigured(good)问题
1.查看raid
[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL -NoLog|grep "Firmware state" Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Unconfigured(good), Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up Firmware state: Online, Spun Up确认出现Unconfigured(good)问题
2.查看各项Count指标
[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PDList –aALL |grep -E "Slot Number|Media Error|Other Error|Predictive Failure Count|Firmware state|Last Predictive Failure Event Seq Number" Slot Number: 0 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 Firmware state: Online, Spun Up Slot Number: 6 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 Firmware state: Online, Spun Up Slot Number: 7 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 Firmware state: Online, Spun Up Slot Number: 8 Media Error Count: 0 Other Error Count: 3 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 Firmware state: Unconfigured(good), Spun Up确认Slot Number值
3.执行导入命令
1.显示所有逻辑磁盘组信息
[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 558.375 GB Mirror Data : 558.375 GB State : Optimal Strip Size : 64 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: No Virtual Drive: 1 (Target Id: 1) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 16.371 TB Mirror Data : 16.371 TB State : Degraded Strip Size : 64 KB Number Of Drives per span:2 Span Depth : 6 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: No Exit Code: 0x00 [root@bj06-08u-node64-103 ~]#2.显示所有的物理信息
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL3.执行导入命令
[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Import -aall Foreign configuration is imported on controller 0. Exit Code: 0x004.执行状态检测命令:
/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall |grep 'Firmware state'
4.查看恢复进度
确认rebuild进度
[root@bj06-08u-node64-103 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog -physdrv[32:8] -a0 Rebuild Progress on Device at Enclosure 32, Slot 8 Completed 2% in 39 Minutes. Exit Code: 0x00